全国免费咨询热线4000-188-588

TEL:029-88643194 FAX:029-88611928

电导率仪的期间核查标准

本文章主要介绍了:电导率仪的期间核查标准,科瑞达电导率仪生产厂家,电导率仪测l硫酸浓度,电导率仪的期间核查标准等信息

4节AA碱性电池或充电电池
温度精度°C
温度范围°C
-5.0...105.0
温度分辨率°C
0.00...80.00ppt
0.01mg/L...600g/L
电导率精度
电导率范围
0.01μS/cm...1000mS/cm
红外接口输出至打印机或电脑(RS232或USB接口)
5-40°C,相对湿度5-80%无冷凝
电导率,盐度,TDS和电阻率的专业测量仪表
(电导率仪的期间核查标准)

在178型的技术基础上,ResMap273是半导体行业首款30毫米桌面四点探针仪。273型扩展了ResMap原来一些产品的性能,实现了太阳能对210毫米大型衬底的要求。外形小巧,坚固耐用,准确性和重复性好。
提供NIST标准片6片!
产品特点:操作简单、快速精确
电阻测量范围:1mΩ/-5MΩ/
典型应用:非晶硅/微晶硅和导电膜电阻率测量;选择性发射极扩散片;表面钝化片;交叉指样PN结扩散片;新型电极设计,如电镀铜电阻测量等
美国CDE专利技术:可针对材料(不同材料、软硬薄膜或离子植入深或浅等条件,对下针状况最佳化。而此功能是可由软见操作,可有0.01mm的分辨率,而非麻烦的硬件调整。
(电导率仪的期间核查标准)

(电导率仪的期间核查标准)

测量值锁定功能:
仪器具有简捷的测量值锁定功能,方便您浏览或记录显示值。在电导率测量模式,按HOLD键,仪器自动锁定当前测量值,再次按键,仪器返回测量模式。
8分钟自动关机程序:
CONscan系列具有自动或手动关机功能,使用时,仪器开机即进入测量模式,如果您在8分钟内没有任何按键操作,仪器将自动关闭电源。
良好的防水性能:
仪器具有良好的防水性能,仪器的每个结构连接点都经过防水处理,即使浸入水中也不会影响使用。同时,仪器的重量经过悬浮力计算,落入水中会自动浮起。
技术参数:
仪器型号:CONscan20
电导率测量范围:0.0~199.9uS/cm
(电导率仪的期间核查标准)

电导率仪检定规程 目录 1范围····································································(1) 2引用文献·······························································(1) 3术语和计量单位··························································(1) 4概述···································································(2) 5计量性能要求···························································(2) 5.1电子单元重复性······················································(2) 5.2电子单元引用误差······················································(2) 5.3电导池常数示值误差···················································2) 5.4温度系数示值误差····················································(2) 5.5温度测量示值误差·····················································(2) 5.6仪器引用误差·······················································(2) 5.7仪器的重复性·························································(2) 6通用技术要求···························································(4) 7计量器具控制···。·······················································4) 7.1检定条件····························································(4) 7.2检定项目···························································(5) 7.3检定方法··························……:···························(5) 7.4检定结果的处理······················································(8) 7.5检定周期····························································(8) 附录A电导率标准溶液浓度及其电导率值····································(9) 附录B电导率仪检定记录示例············································(10) 附录C检定证书内页格式示例·············································(12) 范围 本规程适用于电解质电导率仪的首次检定、后续检定和使用中检验,电阻率仪和基于电导率测量原理的盐度计和总溶解固体含量(TDS)测量仪的校准可参照执行。 引用文献 术语和计量单位 3.1(电解质溶液的)电导 电导池中电解质溶液的例子电荷移动时。电流和电势差的比值 G=IU(1) 式中:G—电导,S I—通过电解质溶液的电流,A; U—电极间的电势差,V 电阻是电导的倒数,单位是Ω 3.2(电解质溶液的)电导率 电解质溶液电导率用以下公式定义: K=jE(2) 式中:k—电导率S?m-1 J—电流密度A?m-2 E—电场强度V?m-1 电阻率是电导率的倒数,单位是欧姆?米(Ω?m) 3.3电导池常数 电导池常数由公式(3)计算 Kcell=lA(3) 式中:Kcell—电导池常数,cm-1 l—测量电极间的有效距离,m
(电导率仪的期间核查标准)

1:电导率仪使用前的检查:检查一下指针是否指零,如果不指零调节电导率仪上的调零旋钮;
2:电导率仪的校准:将电导率仪调节到校正档,指针指向最大刻度;
3:电导率仪的测量:按照电极常数调节旋钮,测量时调节到测量档。
电导率仪的使用注意事项;
1.电极的引线不能潮湿,否则将测不准。
2.高纯水被盛入容器后应迅速测量,否则电导率升高很快,因为空气中的CO2溶入水里变成碳酸根离子。
3.盛被测溶液的容

了解更多关于:电导率测试仪还能叫什么名字,常数为1的电导率仪量程,十gf十电导率仪,电导率仪最新品牌,电导率仪超过量程如何显示,电导率仪校正溶液的选择,离子色谱仪电导率不稳定,在线电导率仪 net,笔试电导率测定仪,dkk电导率仪,电导率仪百科,电导率仪s230使用说明书,电导率仪采购,电导率仪电极用什么浸泡,电导率仪的介绍,电导率仪.环境温度.5-40,在线电导率仪3.0级,测石墨碳棒电导率仪,dds-11a型电导率仪使用,ro出水电导率仪
本文摘自:http://www.oen1718.com 转载请注明出处