全国免费咨询热线4000-188-588

TEL:029-88643194 FAX:029-88611928

自制密度计的刻度间距变化

本文章主要介绍了:自制密度计的刻度间距变化,密度计的刻度间隔,用密度计怎么测量酒度,自制密度计的刻度间距变化等信息

(自制密度计的刻度间距变化)

朱工…手机186-5010-5188……咨询电话4000118588
QQ1:281-6172-923QQ2:283-3586-840
网站:http://www.dx1718.cn
(自制密度计的刻度间距变化)

仪器台间差
0.01D或1%(传统印刷);0.40△Ecmc以内(测量12块BCRA系列色板)
RS-232串联接口,以波特率1200至57600作数据交换
氢化金属镍充电池,充电时间:约3小时
各种机型性能比较表
自动选择功能
纸张偏色及亮度
配色彩品控软件
(自制密度计的刻度间距变化)

荆门工具测量校验-计量所vyhc
荆门工具测量校验-计量所
新消息:仪器校验,流量计检定,食品厂仪器检定,长度仪器校准,力学仪器校准,量具校验,理化仪器校准,电学仪器校准,仪器检定,热工仪器校准
在现有的研究中,均采用数字温度计(或铂电阻温度传感器)作为温度测量标准,仪器校准接线如图2。图2温度校准传感器接线图在开始仪器校准前,将测温标准器的传感器插入测试孔,浸没于油槽中。与测定仪温度传感器并排放置,下端对齐,使测量同一位置的温度,固定于样品支架。如有多个样品支架,则需要在每个支架上固定一个测温标准器。开启测定仪并设置好升温速率后即可开始温度指示误差的仪器校准。现有仪器校准方法描述:启动温度测定仪,观察温度测定仪的温度指示值和标准器的温度读数值,从40℃开始每隔10℃分别记录温度测定仪与标准器的温度读数值,直至温度测定仪达到设定的上限温度。误差按照公式(1):Δt=ti-(ts+t0)(1)式中:Δt—温度测定仪温度指示误。
(自制密度计的刻度间距变化)

KRUSS数字U型管振荡法密度计的测量温度控制?
KRUSS数字U型管振荡法密度计的测量温度控制?
恒温控制:因为液体密度受温度影响大,所以要把实时温度下检测的液体密度换算成20℃时的液体密度。本仪器采用恒温槽控制,把传感器和其所属部件及样液都密封在恒温槽内,通过温度传感器检测振荡管(样液)的温度,便携式密度计,经单片机控制电子元件制冷或制热,保证恒温槽内的温度稳定在20℃±0.1℃范围内。这样不仅解决了换算带来的麻烦和误差,还保证了仪器的测量精度、稳定性以及重复性(可选择我们的循环恒温器进行样品的恒温控制)。
(自制密度计的刻度间距变化)

中华人民共和国国家计量检定规程 JJG955-2000 光谱分析用测微密度计 SpectralAnalysisMicrodensitometer 2000一08一28发布2000一12一01实施 国家质量技术监督局发布 JJG955-2000 光谱分析用测微密度计 产0.0.0.0.0.0.0.O.O.0.0.O.0.O. 检定规程 JJG955-2000 VerificationRegulationofSpectral 飞.0.0.0一0.0.0.o.0.0.o.0.0.0.0.‘ AnalysisMicrodensitometer 本规程经国家质量技术监督局于2000年08月28日批准,并自2000 年12月01日起施行。 归口单位:全国光学计量技术委员会 起草单位:陕西省计量测试研究所 本规程委托全国光学计量技术委员会负责解释 JJG955-2000 本规程主要起草人: 陈俊(陕西省计量测试研究所) 王侠(陕西省计量测试研究所) 李国华〔四川成都发动机(集团)有限公司〕 参加起草人: 陈峻堂(上海光学仪器厂) 周琪(陕西省卫生防疫站) JJG955-2000 目录 1范围··························································································……(1) 2概述·,·,··、·····,·······、·、、·、····,、,、···············,·······、··、···,··、·····、,········,、·····,··…(1) 3技术要求············。·······································································……(2) 3.1外观·················································································,·····……(2) 3.2回零误差···········································································,·····……(2) 3.3示值误差·················································································……(2) 3.4示值的重复性····························。········································。·····……(3) 3.5示值的稳定性···········································································……(3) 3.6电源电压的变化对示值的影响·················
(自制密度计的刻度间距变化)

透光率计、便携式制动性能测试仪和转向参数测试仪、踏板力计、手刹力计都是机动车安全检测机构必配的常规检测仪器。透光率计此款仪器主要用于测量机动车各种玻璃的可见光透光率,具有精确性高、误差小、体积小巧、操作简单等优点,透光率计、便携式制动性能测试仪和转向参数测试仪、踏板力计、手刹力计都是机动车安全检测机构必配的常规检测仪器。透光率计此款仪器主要用于测量机动车各种玻璃的可见光透光率,具有精确性高、误差小、体积小巧、操作简单等优点,且适用范围比较广范。市场上透光率计质量良莠不齐,价格也有很大差距。大家选择透光率计一定要选择正规厂家的产品,不管从产品质量方面,仪器使用寿命、测试准确度还是售后服务方面都是有保障的。专业从事研发生产机动车测试仪器,质量可靠,售后完善,高性价比获得客户一致认可。
(自制密度计的刻度间距变化)

了解更多关于:矿石密度计,土壤密度计k值计算,国标酒精密度计表对应表,吸管制作密度计,证明密度计,自制密度计不能直立在水面,液体密度计哪里有卖,密度计适用范围,颗粒分析密度计法记录,密度计原理ppt,密度计小桶试验,电子测油温密度计,把橡皮泥和筷子做成密度计,爱色丽分光密度计使用说明,密度计的原理使用方法,液体密度计原理,石油产品密度计原理,简易密度计怎么做的步骤,sy-5100b密度计,日本核辐射密度计
本文摘自:http://www.oen1718.com 转载请注明出处