数显压力变送器不显示

本文章主要介绍了:数显压力变送器不显示,沈阳 隔膜压力变送器,供热站压力变送器工作原理,数显压力变送器不显示等信息

显示及背光
LCD显示白色背光
–20°C~60°C
0°C~60°C
抗电磁干扰
1秒/次~600秒/次可选
1-1440分钟可设
按键配置或者远程配置
卡箍式,插入式,螺纹连接
ExdIICT6Gb
目标地址可设
产品功能比较-无线温度传感器
取决于现有运营商基站
取决于NB基站
ZigBee网关
参考当地运营商资费标准
参考当地运营商资费标准
Ip地址及端口可设
高低报警点可设
传感器采集频率可设
上发频率可设
工作状态查询
高低报警点可设
传感器采集频率可设
上发频率可设
工作状态查询
Ip地址及端口可设
高低报警点可设
传感器采集频率可设
(数显压力变送器不显示)

南京索正自动化仪表有限公司位于六朝古都南京,是专业致力于智能工业自动化仪器仪表、新型智能传感器、热电阻/热电阻、隔离器、安全栅、变送器的研发和生产。
公司技术实力雄厚,生产工艺先进,生产检测设备齐全,拥有一批自动化仪表专业工程师及管理人才。在引进国外先进技术和生产工艺的基础上,结合我国国情,不断开拓创新,严格按照IS09001:2000质量体系的过程控制和规范化企业管理,使“索正”智能仪器仪表成为技术起点高,性能优异、品种齐全、质量可靠、售后服务完善,深受广大客户的信赖。
阻尼(阶跃响应):充硅油时,一般在0.2s到1.67s之间连续可调。
(数显压力变送器不显示)

原理:常用的有电容式、谐振梁式、扩撒硅等几种原理!
电容式压力变送器主要有实现压力\电容转换的容室敏感元件及将电容转换成二线制4-20mA电子线路板组成!当过程压力从从测量容室的两侧(或一侧)施加到隔离膜片后,经硅油灌充液传至容室的中心膜片上,中心膜片是个边缘张紧的膜片,在压力的作用下,产生相应的位移,该位移形成差动电容变化!并经过电子线路板的调节、震荡和放大!转换成4-20mA信号输出!输出电流与过程压力成正比!
变送器知识:
压力变送器(pressuretransmitter)是指以输出为准信号的压力传感疒器,是一种接受压力变量按比例转换为标准输出信号的仪表。它能将测压元件传感器感受到的气体、液体等物理压力参数转变成标准的电信号(如4-20mADC等)以供给指示报**仪、记录仪、调节器等二次仪表进行测量、指示和过程调节。
(数显压力变送器不显示)

锥形和螺纹式,适用于F-250-C型蒸压器Autoclave(包括压盖与筛,仅限量程5,SST)
过程连接液件材料
哈氏合金C-276
哈氏合金C-276
惰性液(FluorinertFC-43)
导线管入口尺寸
铝,聚氨酯涂层
铝,聚氨酯涂层
铝,聚氨酯涂层
铝,聚氨酯涂层
M20×1.5(CM20)
M20×1.5(CM20)
2英寸管道安装或面板安装支架,全部SST
危险场所认证
厂家互检(FM)隔爆认证
厂家互检(FM)非易燃与本质安全联合认证
厂家互检(FM)隔爆与本质安全认证
BASEEFA/CENELEC本质安全认证
BASEEFAN类认证
加拿大标准协会(CSA)隔爆与本质安全认证
(数显压力变送器不显示)

如果您对产品不了解,不知道如何选型,可以查看磁翻板液位计选型手册详细版本,如果还是不明白,可以直接电话联系我们销售顾问。
更多产品请点击www.jsmsyb.com磁翻板液位计,uhz带远传磁翻板液位计,浮球液位计,彩色石英管液位计,玻璃管液位计,电磁流量计,一体式/分体式电磁流量计,超声波流量计,涡街流量计,涡轮流量计,压力变送器,差压变送器
(数显压力变送器不显示)

2088型扩散硅压力变送器压力变送器压力敏感核心采用了高性能的硅压阻式压力充油芯体,内部的专用集成电路将传感器毫伏信号转换成标准远距离的传输电流信号,可以直接与计算机接口卡、控制仪表、智能仪表或PLC等方便相连。该系列产品广泛应用于工业过程控制、石油、化工、冶金等行业。1、主要技术参数⑴工作温度:-20℃~80℃;⑵变送器的准确度等级分为:0.1级,基本误差为±0.1;0.3级,基本误差为±0.3;0.5级,基本误差为±0.5(基本误差以量程的百分数表示)。⑶热零点漂移环境温度偏离参比工作条件时,变送器的零点漂移应不大于0.03%FS/℃。⑷热灵敏度漂移环境温度偏离参比工作条件时,变送器的满量程漂移应不大于0.03%FS/℃。⑸绝缘电阻在参比工作条件下,变送器各端子对地之间的绝缘电阻不得低于20Mω/250V。2、外形及安装外形结构见图1,该压力变送器由壳体,放大器,接线端子组成,根据用户的需要可以选用指针表,液晶表头显示。图13、安装方法⑴选择易于操作、维护的地方进行安装;⑵应尽量远离振动源安装;⑶应尽量远离热源的地方安装;⑷直接安装在管道或设备上,安装时用扳手夹紧在变送器六方处。4、电气连接打开仪表后盖(接线端子面),见接线端子,电源连接见图2:
(数显压力变送器不显示)

中华人民共和国国家计量检定规程JJG882-2004压力变送器PressureTransmitter2004一06一04发布2004一12一01实施国家质量监督检验检疫总局发布JJG882-2004、令.心.。.。.令.压力变送器检定规程广O}O}O}d}0}0}0}0}0}0}0}0}0}0}VerificationRegulationofthePressureTransmitterJJG882-2004代替JJG882-1994.六甲.叭诊.武切.扒︾.叭﹀bo、}0.O}0}0}0}0}0}0}O}O}C}O.O}C}O本规程经国家质量监督检验检疫总局于2004年06月04日批准,并自2004年12月01日起施行。归口单位全国压力计量技术委员会主要起草单位上海市计量测试技术研究院参加起草单位杭州天元仪表有限公司本规程委托全国压力计量技术委员会负责解释JJG882-2004本规程主要起草人朱家良屠立猛参加起草人李元上海市计量测试技术研究院上海市计量测试技术研究院杭州天元仪表有限公司JJG882-2004目录1范围··························································································12引用文献····················································································13概述··························································································14计量性能要求··············································································24.1测量误差·················································································24.2回差·······················································。·······························24.3静压影响·················································································25通用技术要求··············································································35.1外观·······················································································35.2密封性····················································································35.3绝缘电阻·················································································35.4绝缘强度·················································································36计量器具控制··············································································46.1定型鉴定或样机试验····························································46.2首次检定、后续检定和使用中检验················································4附录A压力变送器检定时的设备连接方式·································,········9附录B定型鉴定或样机试验试验项目和方法·································11附录C压力变送器检定记录格式······················································17附录D不确定度分析实例·······························································18附录E检定证书、检定结果通知书内页格式·································21JJG882-2004压力变送器检定规程1范围本规程适用于压力包括正、负表压力,差压和绝对压力变送器的定型鉴定或样机试验、首次检定、后续检定和使用中检验。2引用文献本规程引用下列文献JJF1015-2002计量器具型式评价和型式批准通用规范JJF1016-2002计量器具型式评价大纲编写导则JJG875-1994数字压力计检定规程GB/T17614.1-1998工业过程控制系统用变送器第1部分性能评定方法GB/T17626.3-1998射频电磁场辐射抗扰度试验使用本规程时,应注意使用上述引用文献的现行有效版本。3概述压力变送器是一种将压力变量转换为可传送的标准化输出信号的仪表,而且其输出信号与压力变量之间有一给定的连续函数关系通常为线性函数。主要用于工业过程压力参数的测量和控制,差压变送器常用于流量的测量。压力变送器有电动和气动两大类。电动的标准化输出信号主要为OmA一lOmA和4mA一20mA或1V一SV的直流电信号。气动的标准化输出信号主要为20kPa一100kPa的气体压力。不排除具有特殊规定的其他标准化输出信号。压力变送器通常由两部分组成感压单元、信号处理和转换单元。有些变送器增加了显示单元,有些还具有现场总线功能。压力变送器的结构原理如图1所示。压力变送器按原理可分为电容式、谐振式、压阻式、力力矩平衡式、电感式和应变式等。一,显示单元i匕--一}---一压力或差压信号感压单元信号处理和转换单元一卜现场总线输出信号mA,V或kPa图1压力变送器原理框图JJG882-20044计量性能要求4.1测量误差压力变送器的测量误差按准确度等级划分,应不超过表1规定。表1准确度等级及最大允许误差、回差准确度等级最大允许误差/回差/电动气动电动气动0.05士0.050.050.1士0.10.080.20.25士0.2士0.250.160.200.5土0.5士0.50.40.251.0土1.0士1.00.80.51.5土1.5士1.01.20.752.0土2.0土2.01.61.02.5土2.51.25注最大允许误差和回差是以输出量程的百分数表示。4.2回差首次检定的压力变送器,其回差应不超过表1规定。后续检定和使用中检验的压力变送器,其回差应不超过最大允许误差的绝对值。4.3静压影响静压影响只适用于差压变送器。并以输出下限值和量程的变化来衡量。4.3.1力平衡式差压变送器的静压影响应不超过表2规定。表2力平衡式差压变送器静压影响要求项目准确度等级0.51.01.52.0指标输出量程的下限值及量程变化P二蕊6.42.02.53.03.0PwX6.4差压量程簇6kPa3.03.54.06.4v;1输人量P的标准不确定度分量0.35kPa6.4}cA/kPa2.24uA2001.1标准压力发生器0.6kPa万0.35kPa2输人量I的标准不确定度分量3.32P.A13.32PA692.1直流电流表S泌万2.89}A2.89}.A2001.63}eA52.2测量重复性1.63P.AJJG882-2004表D一1续表中i不确定度来源序号;x;不确定度来源;“;x‘的误差分散区间半宽或误差限;k,包含因子;ux;标准不确定度;c;灵敏系数;“‘刃变送器输出的标准不确定度分量,为。}ux;v;自由度。D.6合成标准不确定度由于up和uI彼此间相互独立,因此合成标准不确定度u}DI及有效自由度,。。分别为u}△,二丫。2uP。,I4.OO}.Au4ue△,别eff4/\4/r\“lPl“、t}岁1别2136Ve“取整为iVVoD.7扩展不确定度合成标准不确定度接近正态分布。按置信概率95估计,包含因子可以查t分布得到k9st95veff1.980扩展不确定度由下列计算获得。U95k9su}DI1.98x4.007.9}.AD.8标准器选择和符合性从表D一1可以看出,由标准器带来的合成标准不确定度不包括压力变送器测量的重复性u}DI为3.66}A,自由度376,取整为100。合成标准不确定度u}DI接近正态分布,同样可以查t分布得到k951.98。因此,检定时由标准器带来的扩展不确定度为U951.98uDI7.2}cA被检压力变送器的允许误差为土32}cA。规程中要求检定用标准及配套设备在检定中引人的扩展不确定度U9s应不超过被检压力变送器允许误差绝对值的1/4,即8uA。本例的U95为7.2}cA,因此标准器的选择符合规程要求。JJG882-2004附录E检定证书、检定结果通知书内页格式检定证书内页格式型号规格测量范围输出范围检定环境温度℃相对湿度RH检定地点检定结果检定项目允许误差结论或实际最大误差外观密封性绝缘电阻绝缘强度测量误差回差静压影响E.2检定结果通知书内页格式格式同上,另要求指出不合格项。