全国免费咨询热线4000-188-588

TEL:029-88643194 FAX:029-88611928

隔膜压力变送器安装要求

本文章主要介绍了:隔膜压力变送器安装要求,压力变送器导压管按装图,科隆压力变送器进口品牌,隔膜压力变送器安装要求等信息

罗斯蒙特采用HART协议的2090F卫生型压力变送器pdf,罗斯蒙特采用HART协议的2090F卫生型压力变送器
ProductdataSheet 00813-0100-4698,ReVDA March2008 Rosemount2090F Specifications Ambient 4to185°F(-20to85 Service Storage Liquid,gas,vapor,andhigh-viscosityapplications 22to185°F(30to85° Ranges Processtemperaturesabove185F(85C)requireloweringthe ambientlimitsbya1.5:1ratic URL/Maxspan Maxambienttemperatureinf=Range MinimumSpan Sensorlimit 185-(ProcessTemp-185 1.5psi(103mbar) 30psi(2,06bar) 15 2 7.5psi(517mbar) 150psi(1034bar) 40psi(2,76bar) 300psi(20,68bar) MaxAmbienttemperatureinC 85-(ProcessTemp-85 Output 1.5 c心g Loadlimitations HumidityLimits Maximumloopresistanceisdeterminedbythepowersupplyvoltage 0-100%relativehumidity describedbythefollowingeq MaxLoopResistance=43.5 VolumetricDisplacement (PowerSupplyVoltage-10.5) Lessthan0.00042cmy 1935 Turn-onTime 81500 2.0seconds,nowarm-uprequired T1000 Failureal Operating Region Ifself-diagnosticsdetectasensorormicroprocessorfailure.the analogsignalisdriveneitherhighorlowtoalerttheuser.Highor lowfailuremodeisuser-selectablebyajumperonthetransmitter 0 10.520 Thevaluestowhichthetransmitterdrivesitsoutputinfailure PowerSupplyOutputCodes(dcvolts modedependonwhetheritisfactory-configuredtostandardor NAMUR-compliantoperationThevaluesforeachareasfollows (1)Forhazardouslocationapprovals,power supplymustnotexceed36V. StandardOperation LinearOutput:3.9≤|≤20.8 PowerSupply FailHigh ≥21.75mA Externalpowersupplyrequired.Transmitteroperateson10.5-36 Low: ≤3.75mA vdcwithnoload.Reversepolarityprotectionisstandard NAMUR-CompliantOperation ZeroElevationandSuppression LinearOutput:3.8≤|≤20.5 FailHigh 1>225mA Zerocanbesuppressedbetweenatmosphere(2090FG),oropsia LoW: 1<3.6mA (2090FA)andupperrangelimit,ifthecalibratedspanisequaltoor greaterthantheminimumspan,andtheupperrangevaluedoes notexceedtheupperrangelimit.Novacuumcalibrationsare TransmitterSecurity allowedonthe2090F Activatingthetransmittersecurityfunctionpreventschangestothe transmitterconfiguration,includinglocalzeroandspan OverpressureLimits adjustments.Securityisactivatedbyanintemaljumper Range1:120psigmax Allotherranges:Twicetheupperrangelimit TemperatureLimits Process 4to284F(-20to140°C) 3 Productdatasheet 00813-0100-4698,ReVDA Rosemount2090F March2008 PerformanceSpecifications RFIEffect Lessthan+0.25%ofupperrangelimitfrom20-1000MHzat30 V/mwithleadsinconduit.Lessthan+0.25%ofupperrangelit from20-1000MHzat10V/mwithunshieldedtwistedpair(no ReferenceAccuracy conduit) 0.20%ofcalibratedspanIncludescombinedeffectsoflinearity, hysteresis,andrepeatability Physicalspecifications AmbientTemperatureEffectper100F(56C) ElectricalConnection +(0.3%URL+0.3%ofspan)from-40to185F(-40to85C 1/2-14NPT,PG13.5,orM20X1.5(CM20)conduitentry Stability ProcessWettedparts +o10%ofupperrangelimitfor12months IsolatingDiaphragm TimeResponse 316stainlesssteel Lessthan200mstimeconstant(63.2%responsetoastep ProcessConnector changeinpressure) 316Lstainlesssteel Vibrationeffect Non-wettedParts ofpeaktopeakconstantdisplacementof4mm(5-15Hzango, Lessthan+o.1%ofupperrangelimitwhensubjectedtovibration Electronicshousin ng constantaccelerationof2g(15-150Hz)and1g(150-2000Hz) Low-copperaluminum,NEMA4X,IP65,IP67 CSAenclosureType4X PowerSupplyEffect Lessthan0.01%ofcalibratedspanpervolt Paint Polyurethane MountingPositionEffect Zeroshiftofupto1.2inH2o(0,3kPa),whichcanbecalibrated CoverO-rings out.Nospaneffect Buna-N Productcertifications ApprovedManufacturingLocations EuropeanPressureEquipmentDirective(PED)(97/23/EC) Rosemountinc-Chanhassen.Minnesota.USA 2088/2090PressureTransmitters SoundEngineeringPractice EmersonProcessManagementGmbHCo-Wessling ElectroMagneticCompatibility(EMC)(2004/108EC) EmersonProcessManagementAsiaPacific All2088/2090SmartPressureTransmitter PrivateLimited-Singapore EN61326-1:1997withAmendmentsa1.a2andA3 BeijingRosemountFarEastInstrumentCo.,LTD-Beijing,China OrdinaryLocationCertificationforFactoryMutual EuropeanUnionDirectiveInformation Asstandardthetransmitterhasbeenexaminedandtestedto determinethatthedesignmeetsbasicelectrical,mechanical TheecdeclarationofconformityforallapplicableEuropean directivesforthisproductcanbefoundontherosemountwebsite andfireprotectionrequirementsbyFM,anationallyrecognized testinglaboratory(NRTL)asaccreditedbytheFederal atwww.rosemount.com.ahardcopymaybeobtainedby contactingourlocalsalesoffice OccupationalSafetyandHealthAdministration(OSHA) ATEXDirective(94/9/EC) EmersonProcessManagementcomplieswiththeATEX Directive ProductdataSheet 00813-0100-4698,ReVDA March2008 Rosemount2090F Hazardouslocationscertifications NDATEXCombustibledust Certificateno:BAS01ATE×1427X@‖1D NorthAmericanCertifications T105°c(Tamb=-20°Cto85°c P66 FactoryMutual(FM)Approvals 〔∈1180 E5Explosion-ProofforClassI,Division1,GroupsB,C,andD ∨maX=36ydcmax Dust-Ignition-ProofforClassll,Division1,GroupsE,F,G, -24mA Classll,Division1,indoorandoutdoor(NEMA4X) SpecialConditionsforSafeUse(x): hazardouslocations,factorysealed 1.Theusermustensurethatthemaximumratedvoltage 15IntrinsicallysafeforuseinClassI,Division1,GroupsA,B, andcurrent(36volts,24mA,D.C.)arenotexceeded.Al C,D;Classll,Division1,GroupsE,F,andG;andClassIll connectionstootherapparatusorassociatedapparatus Division1whenconnectedinaccordancewithrosemount hallhavecontroloverthisvoltageandcurrentequivalent drawing02088-1018Non-incendiveforClassI,Division2, toacategory"ib"circuitaccordingtoEN50020 GroupsA,B,C,andD 2.Cableentriesmustbeusedwhichmaintaintheingress Forinputparametersseecontroldrawing02088-1018 protectionoftheenclosuretoatleastIP66 3.Unusedcableentriesmustbefilledwithsuitableblanking CanadianStandardsAssociation(CSA plugswhichmaintaintheingressprotectionofthe C6Explosion-ProofforClassI,Division1,GroupsB,C,andD enclosuretoatleastiP66 Dust-Ignition-ProofforClassll,Division1.groupse,f,G 4.Cableentriesandblankingplugsmustbesuitableforthe Classlindoorandoutdoorhazardouslocations.CSA ambientrangeoftheapparatusandcapableot enclosureType4X;factorysealed.SuitableforClassI withstandinga7Jimpacttest Division2,GroupsA,b,C,andD 5.the2088/2090sensormodulemustbesecurelyscrewed ntrinsicallySafeforClassI,Division1,GroupsA,B,C,and inplacetomaintaintheingressprotectionofthe D.Temp.CodeT3CIntrinsicallysafewhenconnectedwith enclosure approvedbarriersinaccordancewithRosemountdrawing EDATEXFlameproof 088-1024 CertificationNo.KEMA97ATEX2378EI11/2G Forinputparametersseecontroldrawing02088-1024 EExd|cT6(a=20°cto40°c EuropeanCertifications T4(a=20°cto80°c) 〔∈1180 11ATEXIntrinsicSafety Vmax=36(withSmartoutputoption CertificateNo.BASOOATEX1166X111G Vmax=14(withlowpoweroutputoption) EEXiaCT5(Tamb=-55to40C) EEXialICT4(Tamb=-55to70'C) JapaneseCertifications ∈1180 E4TlISFlame-Proof TABLE1InputParameters Exd|CT6(Tamb=85°℃C) Loop/Power InputType CertificateDescription Smart C158702090FwithSSTwettedparts(withmeter) l;=200mA Smart C15878 2090FwithSSTwettedparts(nometer) P;=0.9W Combinationsofcertifications C1=0.012uF Smart Stainlesssteelcertificationtagisprovidedwhenoptionalapproval SpecialConditionsforSafeUse(x: isspecified.Onceadevicelabeledwithmultipleapprovaltypesis Whentheoptionaltransientprotectionterminalblockis installed,itshouldnotbereinstalledusinganyotherapproval installed,theapparatusisnotcapableofwithstandinga types.Permanentlymarktheapprovallabeltodistinguishitfrol 500Vrmstesttocase.Thismustbetakenintoaccounton unusedapprovaltypes anyinstallationinwhichitisused,forexamplebyassuring KBCombinationofe5.5.andc6 thatthesupplytotheapparatusisgalvanicallyisolated KHCombinationofe5.5and1 N1ATEXTypen K5Combinationofe5and5 CertificationNo.BAS00ATE×3167X@‖3G K6Combinationofc6.1andeD EEXnLIICT5(a=-40°cto70°c) ui=50Vdcmax c∈ Specialconditionsforsafeuse Whentheoptionaltransientprotectionterminalblockis installed,theapparatusisnotcapableofwithstandinga500 Vr.m.s.testtocase.Thismustbetakenintoaccountonany installationinwhichitisused,forexample,byassuringthat hesupplytotheapparatusisgalvanicallyisolated 5 Productdatasheet 00813-0100-4698,ReVDA Rosemount2090F March2008 DimensionalDrawings Rosemount2090FTransmitterExplodedview CertificationLabel LocalZeroandspan ElectronicsHousingAssembly. Terminalblock- Cover ElectronicsBoard Alarm Jumper LCD [町 SecurityJur OPTIONALSMARTLCDDISPLAY Rosemount2090F 50125) Certificati Optional Tag 4.3(110) Meter 39(100) ROSEMOU了 4.7 Transmitter (120) Terminal cuntry Connections Side Sid 0×1.5Female(M20) 2×14-20UNc-2BX andpg13.5alsoavail Depth0.60 ableasoptions MountingHoles NOTE 12or2-in.Tri-Clamp Dimensionsareininches(millimeters Connection 6 ProductdataSheet 00813-0100-4698,ReVDA March2008 Rosemount2090F OrderingInformation ModelProductDescription 2090FSanitaryPressureTransmitter TransmitterType A Absolute Gage CodeRange MinimumSpan URL/MaxSpanSensorLimit 0-30psi(0-2bar) 1.5psi(103mbar) 30psi(2,06bar) 0-150psi(0-10.3bar) 7.5psi(517mbar) psi(10,34bar 30-300psi(0-20.7ba) 40psi(2,76bar) 300psi(2068bar) CodeOutput 4-20madc/DigitalHARTProtocol CodeMaterialofconstruction Processconnection Isolatingdiaphragm Oilfill 2D 16LSST 316LSST Neobee CodeProcessConnection EF 1/2-in.Tri-ClampConnection 2-in.Tri-ClampConnection CodeConduitthread 12-14NPT 2 M20×15cM20) PG13.5 Code Options DigitalDisplay M5 LCDdisplayscaled0-100% LCDdisplay,specialconfiguration MountingBrackets B4SSTmountingbracketwithSSTBolts Productcertifications ATEXIntrinsicSatety N1 ATEXTypen NDATEXDuSt ED ATEXFlameproof C6CSAExplosion-Proof,IntrinsicallySafe,andNon-incendive CSAExplosion-Proof,DustIgnition-proof,IntrinsicallySafe,Division2 E5FMExplosion-Proof,DustIgnition-proof FMIntrinsicallysafe,Division2 K5 FMEXplosion-Proof,dustignition-proof,IntrinsicallySafe,Division2 KB FMandCSAExplosion-Proof,DustIgnition-proof,IntrinsicallySafe,Division2 KHFMApprovalsandATEXExplosion-ProofandIntrinsicallySafe NK IECEXDust K77n7.E7&NKCombination K1 IlN1.ed&NDCombination Terminalblocks T1TransientProtection SpecialCertifications Calibrationcertificate SpecialConfiguration(Software) NAMURalarmandsaturationlevels,highalarm cnNaMURalarmandsaturationlevelslowalarm SpecialProcedures P2 CleaningforSpecialService 0.1%Accuracyto10:1Turndown picalModelNumber:2090FG2s2DE1 Productdatasheet 00813-0100-4698,ReVDA Rosemount2090F March2008 Calibration Transmittersarefactorycalibratedtocustomer's specifiedrange.Ifcalibrationisnotspecified transmittersarecalibratedatmaximumrange Calibrationisatambienttemperatureandpressure Tagging Thetransmitterwillbetagged,atnocharge,in accordancewithcustomerrequirementsalltagsare stainlesssteel.Thestandardtagiswiredtothe transmitter.Tagcharacterheightis18inch(0.318 cm).Apermanentlyattachedtagisavailableupon request StandardTermsandconditionsofsalecanbefoundatwwrosemountcomltermsofsale TheemersonlogoisatrademarkandservicemarkofEmersonElectricCo RosemountandtherosemountlogotypeareregisterdtrademarksofRosemountinc NeobeeisaregisteredtrademarkofstepanChemicalCo Tri-ClampisaregisteredtrdemarkofTri-CloverInc.ogtheAlfa-LavalGroup The3-Asymbolisaregisteredtrademarkofthe3-ASanitaryStandardsSymbolsCounci. Allothermarksarethepropertyoftheirprospectiveowners CoverPhoto:2090-0014AB EmersonProcessManagement Rosemountinc EmersonProcessManagementEmersonProcessManagementAsia 8200MarketBoulevard Heathplace PacificPrivateLimited Chanhassen,MN55317UsaBognorRegis 1PandanCrescent T(U.s.)4000118588 WestSussexPO229SH Singapore128461 International)(952)9068888England T(65)67778211 F(952)9497001 T44(0)4000118588 F(65)67770947 F44(0)4000118588 Enquiries@ap.emErsoNProcess.com www.rosemountcom EMERSON o2008RosemountInc.Allrightsreserved ProcessManagement
(隔膜压力变送器安装要求)

WP-GP6E12M1B1D1ND5远传压力差压变送器、CNNK-503、CHNJ-115GPJ/T7、LG-STA11变送器、CHNJ-HRN801-1-0/X2/PID、乐至CHPK-72昌晖自动化
南京昌晖自动化仪表有限公司代理销售:香港东辉仪表大延牌仪器仪表、香港昌晖仪器仪表、香港晖祥仪器仪表、福建虹润精密仪器仪表、福建上润精密仪器仪表、福建天弘仪器仪表、香港辰润仪器仪表、厦门安东仪器仪表、江阴远大仪器仪表、北京昆仑天辰仪器仪表、麦克传感器、美国麦德胜仪器仪表、威尔泰压力变送器、浙江宇邦阀门、青云自控阀门等。南京昌晖总部位于风景秀丽、龙蟠虎踞的六朝古都南京,坐落于南京市六合经济开发区、公司是集研发生产销售、成套工程为一体的有限公司。本公司技术力量雄厚,拥有一批专业的自动化仪表工程师及管理人才、主要产品:各种热电偶/阻、耐磨热电偶、热风炉热电偶、普通压力表、真空压力表、耐震压力表、电接点压力表,膜盒压力表、隔膜压力表、电磁/涡街/孔板流量计、金属转子流量计、超声波流量计/液位计、浮球液位控制器、磁翻板液位计、双金属温度计、电接点双金属温度计、差压/压力/液位变送器、防腐型压力/液位变送器、一体化液位变送器、一体化温度变送器、氧化锆氧量分析仪、智能数字(光柱)显示控制仪、多路巡检仪、流量积算仪、彩色无纸记录仪、各种隔离器、配电器、安全栅、电流/电压变送器、HXWP香港晖祥仪表、晖祥仪表、晖祥自动化、晖祥仪表、河南晖祥、SWP香港昌晖仪表、昌晖仪表、福州昌晖、福建昌晖、昌晖自动化、天长昌晖、郑州昌晖、天津昌晖、上海昌晖、WP香港上润仪表、上润仪表、LU安东仪表、安徽天康仪表、EJA横河变送器、DY2000大延牌、ROSEMOUNT罗斯蒙特变送器、WT威尔泰压力变送器、DY东辉仪表、香港东辉、福建东辉、福州东辉、HR/NHR虹润仪表、NHR新虹润、福建虹润、香港虹润、AI宇电仪表、重庆川仪、横河YOKOGAWAEJA变送器、上海自动化仪表、昆山市高新、宁波柯力传感器、英国传力传感器、CCS压力开关、西门子、和利时模块等。
(隔膜压力变送器安装要求)

≤±0.15%FS/年
≤±0.05%FS/℃
≤500ms(标准)
200-1000ms可调
电气参数()
电流2线制:4~20mA;0~20mA
电压3线制:0~5V;1~5V;0~10V;1~10V;
DC24V(12~32VDC,更低可洽谈)
电流输出型:≤500Ω
电压输出型:输出抗阻≤250Ω
PG9贺斯曼接头,M20*1.5穿线孔(配锁母)
1100T型:四位LED显示
2088T型:四位半LCD显示,字高120mm;蓝底白字长亮型LCD
4-20mA+Hart;RS485(Modbus)
氟橡胶,可选:EPOM、NBR
316L不锈钢
M20*1.5,其他可选
IP65或IP68
-30~120℃(散热片型)
-30~150℃(弯管型)
108RMS(25~2000Hz)
(隔膜压力变送器安装要求)

2090FG2S2DF1M5B4Q4
8705TSA040SEW0N0Q4
3051TG1A2B21LS1/1199WNA95SSLSG0LA00
065N02N0000N0315XA
065N01N0000N0265XA
3051CD2A22A1CS2M5B4/1199DNB58DFFWJGDA00
3051S1CD2A5C11A1AE5M5Q4
8721ASA040UC2NA+8732EST1A1NAM4
2090FG2S2DF1M5
8721ASA030UC2NA+8732EST2A1NAM4
3051CD3A22A1BS2M5B4
2051CD1A221AD4
3051CD2A22A1KB4M6E5QTT1S2Q4Q8HR5/1199DDN10GFFWG5KB00/5DA00/6KB00/6DB00
2051CD4A22A1KB4E5M5
2051TG4A2B21JM5P1E1Q4Q8
2051TG5A2B21JM5P1E1Q4Q8
3051GP2A2B21AB4
3051TG4A2B31JB4K5M6Q4Q8
(隔膜压力变送器安装要求)

意赛德(天津)自动化仪器有限公司 General EJA510E&EJA530E Specifications 一一般般规规格格书书绝压&压力变送器 EJA510E/EJA530E高性能绝对压力和压力变送器采用 单晶硅谐振式传感器技术,适用于测量液体、气体或 蒸汽的流量、液位、密度和压力。EJA510E/EJA530E 将压力转换成4~20mADC电流信号输出,具有快速响 应、远程设定、自诊断等功能。 EJA-E系列产品提供BRAIN、HART/HART(1~5VDC) 低功耗型、FF现场总线及PROFIBUSPA等通讯协议, 标准配置通过SIL2安全认证。 ■标准规格 带“?”符号的现场总线,FF通讯参阅GS01C31T02-01CN; PROFIBUSPA通讯参阅GS01C31T04-01CN。 □量程和范围 (对于EJA510E型,测量值是绝对压力值,下限为0) 测量psibarkg/cm规格一致性 MPa 量程/范围(/D1)(/D3)(/D4)EJA-E系列确保至少为±3σ的一致性。 10~200 量程1.45~290.1~20.1~2调校量程的参考精度 kPa A(包括基于端基的线性、滞后性和重复性) ?100~200 范围?14.5~29?1~2?1~2 kPa参考精度 测量量程 量程0.1~214.5~2901~201~20量程≥X量程(隔膜压力变送器安装要求)

8、注意保护变送器引出电缆。在工业现场使用时,建议使用金属管保护或者架空。
的常见故障:
压力变送器在使用过程中难免出现各种各样的故障,其影响因素众多,例如压力变送器内隔片与传感原件间存在灌充液漏,零点和量程偏移、输出不稳定等都会导致压力变送器精度下降甚至发生损坏;天气因素也会对变送器造成影响,如雷击会损坏变送器膜盒的电路、导致无法通讯;潮湿的环境会损坏线路;变送器量程选择不合理会造成感压元件不可逆的变形。以下介绍几种常见的故障类型:
(1)线路故障。当出现线路故障时,计算机显示数值出现异常,将变送器接线盒打开,检查线路是否存在虚接、短接或者断接的现象,在采用测电源、摇绝缘以及量电阻等方法排查故障。
(隔膜压力变送器安装要求)

7、是否需要具备互换性的变送器
确定所需的变送器是否能够适应多个使用系统。一般来讲,这一点很重要。尤其是对于OEM产品。一旦将产品送到客户手中,那么客户用来校准的花销是相当大的。如果产品具有良好的互换性,那么即使是改变所用的变送器,也不会影响整个系统的效果。
8、变送器超时工作后需要保持稳定度
大部分变送器在经过超时工作后会产生“漂移”,因此很有必要在购买前了解变送器的稳定度,这种预先的工作能减少将来使用中会出现的种种麻烦。
9、变送器的封装
变送器的封装,尤其往往容易忽略是它的机架,然而这一点在以后使用中会逐渐暴露出其缺点。在选购传送器传一定要考虑到将来变送器的工作环境,湿度如何,怎样安装变送器,会不会有强烈的撞击或振动等。
(隔膜压力变送器安装要求)

了解更多关于:压力变送器校验仪型号,压力变送器工作原理及结构,压力变送器是不是属于强检,工业压力变送器生产商,压力变送器厂家招工,压力变送器规格,12v供电的压力变送器,压力变送器型号3051,压力变送器安装直段尺寸,压力变送器外壳材质,DN15压力变送器,压力变送器按不同的转换原理,压阻式 压力变送器原理,法兰式插筒压力变送器,压力变送器压力不稳怎么回事,瑞士富巴压力变送器,压力变送器可以有,压力变送器壳体功能,压力变送器能否更换膜片,蒸汽压力变送器接线图
本文摘自:http://www.oen1718.com 转载请注明出处